Fittings & options

PVDF Tank Fittings & Options

Welded fittings are molded from the same PVDF as your tank, so they share its chemical resistance. We install every fitting and accessory at our Willis, Texas plant, so your tank arrives ready to connect.

✓ Welded PVDF couplings & flanges   ✓ Bulkheads & valves   ✓ Level, leak & heat options

Browse Fittings Check Your Chemical

Downloads

Fittings & Options Spec Sheets

Download spec sheets for the fittings and options we install on PVDF (Kynar) storage tanks at our Willis, Texas plant. Each sheet covers materials, sizes and how the fitting is installed. Email dmiller@plasticstoragetanks.com if you need a sheet that isn't listed.

Pipe connection fittings

Valves & piping

Vents & lids

Connections

Welded & Bulkhead Fittings

Welded fittings are fused to the tank wall in matching PVDF for a leak-free, chemical-resistant connection.

PVDF welded threaded coupling on a plastic tank1″ – 4″ FNPT

Welded Couplings

PVDF couplings welded into the tank wall, with a female NPT thread for your piping.

Gusseted PVDF welded flange on a tank1″ – 10″ ANSI 150#

Welded Flanges

Gusseted PVDF flanges welded to the tank with Vanstone rings, drilled to ANSI 150# bolt patterns.

Large bolted welded flange on a plastic storage tankUp to 10″

Large Outlet Flanges

Large-diameter welded flanges for high-flow outlets and transfer lines.

PVDF bulkhead fitting for plastic tanks½″ – 4″

Bulkhead Fittings

The most common tank fitting. The fitting material and gasket (Viton®, EPDM or Buna-N) are chosen to match your chemical. PVC and CPVC bulkheads can be threaded or socket (glued); polypropylene bulkheads are always threaded.

Self-aligning bulkhead for tank domes2″ – 3″ · Top only

Self-Aligning Bulkheads

Seals on the curved dome of the tank, for top-of-tank connections only.

Sanitary Tri-Clamp adapter½″ – 4″

Sanitary Tri-Clamps

Quick-disconnect sanitary connections for clean and high-purity service.

Bolted spool flange fitting

Bolted & Spool Flanges

A bolted flange through the tank wall, an alternative where a welded flange isn’t the right fit.

Valves & vents

Valves, Vents & Fill Lines

PVDF bolted ball valve150 psi · PTFE seats

Ball Valves

Bolted ball valves with PTFE seats and locking handles, rated 150 psi, in a material chosen for your chemical.

Screened U-vent for a plastic storage tank2″ · 3″ · 4″

Screened U-Vents

Every atmospheric tank needs a vent. U-vents keep rain and debris out while the tank breathes.

Diagram of a top fill line on a plastic tank

Top Fill Lines

Fill from ground level through a line that runs up the sidewall and into the top of the tank.

Diagram of a top siphon drain line

Top Drain Lines

Draw liquid from the top of the tank without a sidewall fitting below the liquid level.

Monitoring

Level & Leak Monitoring

Diagram of a reverse float level indicator

Reverse Float Level Indicators

A simple, non-electric gauge: the float rides the liquid and an outside indicator shows the level.

Ultrasonic level transmitter

Ultrasonic Level Sensors

Non-contact ultrasonic level measurement with an optional display and controller.

Interstitial leak detector with strobe alarmDouble wall tanks

Interstitial Leak Detectors

For double wall tanks. A probe between the walls sounds an alarm, flashes a strobe and can signal your PLC.

Thermal

Insulation & Heat Tracing

Spray-foam insulated vertical storage tankR-6.7 per inch

Spray-Foam Insulation

Closed-cell polyurethane foam sealed with a UV-resistant white mastic. 2″ standard; 3″ and 4″ optional.

Heat trace pads and controller on a plastic tank

Heat Tracing

Heat trace pads and a temperature controller hold your chemical at temperature and prevent freezing.

Installation & safety

Installation & Safety

Tie-down cable layout on a vertical tank120 mph

Wind & Seismic Tie-Downs

Galvanized cable tie-down systems for vertical tanks under 5,000 gallons, rated for 120 mph winds.

Molded tie-down lug with cable and anchor

Molded Tie-Down Lugs

Lifting and tie-down lugs are molded into the tank for secure anchoring.

Safety note

Oxidizing Chemicals

We do not install welded flanges in the sidewalls of tanks storing nitric acid, sodium hypochlorite, sulfuric acid or other oxidizers. We will recommend the right fitting for your chemical.

Match Fittings to Your Chemical

Gasket and fitting materials depend on what you store. Check the ratings, then pick your tank.

Chemical CompatibilityPVDF Tanks
Questions about PVDF? Send the chemical, concentration, temperature and your SDS and we will confirm the tank, fittings and gaskets.
Request a Quote Call 936-228-1520