polystoragetank.com › Fittings & Options › Pumps for Water and Chemical Tanks
| Gravity-fed (flooded suction) | Self-priming (suction lift) | |
|---|---|---|
| Where the liquid is | Above the pump. It flows into the pump on its own. | Below the pump. The pump has to pull it up. |
| Typical tank outlet | Bulkhead fitting or flange in the sidewall near the bottom, or a bottom outlet on a cone bottom tank | A top drain line or suction pipe coming out through the top of the tank |
| Priming | Open the tank valve and the pump fills itself | The pump must clear air out of the suction line before liquid arrives |
| Pumps that work | Nearly any pump, including standard centrifugal pumps | Only pumps built to self-prime (see the table below) |
A gravity-fed setup is the easiest on a pump. With liquid always at the inlet, the pump never runs dry while the tank has liquid in it, and it does not have to fight suction lift.
| Pump type | Needs gravity feed? | Common tank uses |
|---|---|---|
| Standard centrifugal (end suction, close-coupled) | Yes. It cannot pull air out of a suction line. | Water transfer, irrigation, wash water, high flow |
| Magnetic drive (mag drive) centrifugal | Yes (standard models). Sealless, so nothing leaks past a shaft seal. | Acids, caustic, bleach and other chemical transfer |
| Multistage and booster pumps | Yes, unless the maker says the model self-primes | Pressurized water from a storage tank, with a pressure tank or variable speed drive |
| Air-operated double diaphragm (AODD) | No. Self-priming and can run dry. | Chemical transfer, thick liquids, slurries |
| Peristaltic (hose) pump | No. Self-priming and can run dry. | Chemical dosing, abrasive or viscous liquids |
| Diaphragm metering (dosing) pump | No, but gravity feed makes it more accurate and reliable | Feeding chlorine, caustic, acid or coagulant at a set rate |
| Self-priming centrifugal | No. Fill the casing once and it re-primes itself. | Water and chemical transfer where the pump sits above the liquid |
| Gear, rotary vane, progressive cavity | No, but most should not run dry | Oils, glycol, liquid feed and other thick liquids |
Any of these pumps can be fed by gravity. Only the self-priming ones can also lift liquid. If your tank has a top drain line, as most double wall tanks do, see our self-priming pump guide for double wall tanks.
We can put the outlet where your pump needs it and match the fitting size to the pump inlet. See fittings and options.
| Job | Pump to look at |
|---|---|
| Water pressure for a house, shop or barn | A booster pump (often multistage centrifugal) with a pressure tank or a constant-pressure controller |
| Rainwater use and irrigation | A centrifugal or booster pump; a submersible pump inside the tank is another option |
| Livestock watering | Often no pump at all: set the tank above the trough and let gravity and a float valve do the work. See livestock water tanks. |
| Drinking water | A pump certified to NSF/ANSI 61 for potable water, with a tank in FDA-approved resin. See water tanks. |
| Fire protection | The fire department drafts from the tank with its own pumper. See fire water tanks. |
For chemical service, every wetted part of the pump (body, impeller or diaphragm, seals and O-rings) has to resist the chemical. Ratings from our chemical compatibility chart:
| Chemical | What to look for in the pump |
|---|---|
| Sodium hydroxide (caustic) | Polypropylene or HDPE wetted parts; EPDM or Buna-N seals. Avoid Viton, PVDF and aluminum or zinc parts. |
| Sodium hypochlorite (bleach) | PVDF, PVC or CPVC wetted parts; Viton seals. Avoid 316 stainless steel, and Buna-N with strong hypochlorite. Bleach gives off gas that can air-lock a metering pump, so choose one with a degassing valve. |
| Acids | Match the acid and strength: PVDF for concentrated sulfuric and nitric acid; polypropylene or PVDF for most dilute acids. |
| Ethylene glycol | Most plastics and EPDM, Buna-N or Viton seals are rated excellent; 316 stainless steel is rated good. |
Check the pump maker’s own chemical guide too, at your strength and temperature.
Heavy liquids need more motor. Centrifugal pump curves are drawn for water. A liquid heavier than water takes more power to move: about 1.5 times the horsepower at 1.5 SG, and about 1.84 times for concentrated sulfuric acid. Give the pump supplier the specific gravity so the motor is sized right.
A pump installed below the liquid it pumps, so the liquid flows into it by gravity (also called flooded suction). On a poly tank, that means a pump connected to an outlet near the bottom of the tank.
Not if the pump is fed from a bottom or low sidewall outlet. You need a self-priming pump when the pump sits above the liquid, such as on a top drain line or a suction pipe through the top of the tank.
Yes, when it is gravity fed. A standard centrifugal pump cannot lift liquid on its own, so it needs liquid at its inlet from an outlet low on the tank.
Mag drive centrifugal pumps and air-operated double diaphragm (AODD) pumps are the most common. Choose wetted parts rated for your chemical, and give the supplier the chemical, strength, temperature and specific gravity.
No. We build the tank and install outlets sized and placed for the pump you choose. This guide is here to help you pick a suitable pump.
★ Made in the USA ★ Willis, Texas ★