Home › Fittings & Options
Welded fittings are molded from the same PVDF as your tank, so they share its chemical resistance. We install every fitting and accessory at our Willis, Texas plant, so your tank arrives ready to connect.
✓ Welded PVDF couplings & flanges ✓ Bulkheads & valves ✓ Level, leak & heat options
Browse Fittings Check Your ChemicalDownloads
Download spec sheets for the fittings and options we install on PVDF (Kynar) storage tanks at our Willis, Texas plant. Each sheet covers materials, sizes and how the fitting is installed. Email dmiller@plasticstoragetanks.com if you need a sheet that isn't listed.
Connections
Welded fittings are fused to the tank wall in matching PVDF for a leak-free, chemical-resistant connection.
1″ – 4″ FNPTPVDF couplings welded into the tank wall, with a female NPT thread for your piping.
1″ – 10″ ANSI 150#Gusseted PVDF flanges welded to the tank with Vanstone rings, drilled to ANSI 150# bolt patterns.
Up to 10″Large-diameter welded flanges for high-flow outlets and transfer lines.
½″ – 4″The most common tank fitting. The fitting material and gasket (Viton®, EPDM or Buna-N) are chosen to match your chemical. PVC and CPVC bulkheads can be threaded or socket (glued); polypropylene bulkheads are always threaded.
2″ – 3″ · Top onlySeals on the curved dome of the tank, for top-of-tank connections only.
½″ – 4″Quick-disconnect sanitary connections for clean and high-purity service.

A bolted flange through the tank wall, an alternative where a welded flange isn’t the right fit.
Valves & vents
150 psi · PTFE seatsBolted ball valves with PTFE seats and locking handles, rated 150 psi, in a material chosen for your chemical.
2″ · 3″ · 4″Every atmospheric tank needs a vent. U-vents keep rain and debris out while the tank breathes.

Fill from ground level through a line that runs up the sidewall and into the top of the tank.

Draw liquid from the top of the tank without a sidewall fitting below the liquid level.
Monitoring

A simple, non-electric gauge: the float rides the liquid and an outside indicator shows the level.

Non-contact ultrasonic level measurement with an optional display and controller.
Double wall tanksFor double wall tanks. A probe between the walls sounds an alarm, flashes a strobe and can signal your PLC.
Thermal
R-6.7 per inchClosed-cell polyurethane foam sealed with a UV-resistant white mastic. 2″ standard; 3″ and 4″ optional.

Heat trace pads and a temperature controller hold your chemical at temperature and prevent freezing.
Installation & safety
120 mphGalvanized cable tie-down systems for vertical tanks under 5,000 gallons, rated for 120 mph winds.

Lifting and tie-down lugs are molded into the tank for secure anchoring.
We do not install welded flanges in the sidewalls of tanks storing nitric acid, sodium hypochlorite, sulfuric acid or other oxidizers. We will recommend the right fitting for your chemical.
Gasket and fitting materials depend on what you store. Check the ratings, then pick your tank.
Chemical CompatibilityPVDF Tanks★ Made in the USA ★ Willis, Texas ★